01 · GPUs
NVIDIA- GB300 NVL72
- GB200 NVL72
- HGX B300 / B200
- HGX H200 / H100
- RTX PRO 6000 Blackwell
Technology
A PortaDC is one machine. Cooling loop, boundary controller, scheduler, operating record and armour are designed and tested together before the pod leaves the factory. Electricity in and heat out are measured from the first run.
Liquid cooling
Direct-to-chip cold plates take most of the heat; in-row air takes the rest. The loop is closed, so there is no water to source and none to waste after the first fill.
Direct to chip
Most of the heat
In-row air
The remainder
The dry cooler
On the roof
The result
1.10 – 1.21 Design PUE
SYS // 04 · FrontierGate™ + LARUS AI
A brushed-gunmetal unit, patent pending, in every pod. FrontierGate™ enforces strict electrical isolation between the host asset and the compute vault in sub-millisecond windows, so the tenant's firm floor never moves. LARUS AI™ signs boundary power and thermal delivery into the operating record a lender, a host and a tenant read.

01 // The cushion, executed at the boundary
The host's own load ramps toward the approved boundary. FrontierGate™ holds the host's power boundary while the tenant's firm floor never moves. A Surge tenant receives the flexible-band signal and answers with its own orchestration; a Pulse tenant feels nothing.
02 // The buffer carries the cushion
At the 45 °C design ambient the pod holds supply coolant at or below 35 °C through a host call, with a 50 °C survival margin above that. The host gets its flexibility; the tenant never feels it.
03 // Two channels, hardware-signed
LARUS AI™ cryptographically signs boundary power and thermal delivery into a single auditable ledger, alongside independent hardware fault isolation. Two parties read the one record: the tenant for its invoice and SLA, the host for its boundary and settlement.
SYS // 05 · Four layers
Sited inside fenced, 24/7 monitored solar-and-battery switchyards or secured industrial premises. No public foot traffic.
Solid corrugated weathering-steel walls with no air-intake louvres, internal deadbolts, vibration sensing and clean-agent fire detection and suppression to Australian standards.
LARUS AI™ hardware-signs boundary power and thermal delivery into one auditable ledger. Tamper-linked telemetry and independent hardware fault isolation sit alongside.
Every pod passes witnessed factory acceptance testing before it ships, then Australian integration and certification: AS/NZS 61439 switchboard, revenue-grade boundary metering, fire detection and suppression to Australian standards, statutory AS/NZS 3000 certification and site acceptance sign-off.
Pre-plumbed
Every rack in the lineup plugs into the same pod. Change the silicon; keep the pod. You bring it; we never touch it.
01 · GPUs
NVIDIA02 · GPUs
AMD03 · Servers
Dell04 · Servers
HPE05 · Servers
Supermicro06 · Servers
Lenovo07 · Servers
Gigabyte08 · Networking
Broadcom09 · Networking
AristaThird-party brands and models identify compatible hardware, interfaces and specification standards only. No affiliation, endorsement or partnership is implied.
Next
Walk the pod on the PortaDC page, or tell us the workload and we'll configure one for you.